| Inspection Test Plan |
| |
| FINISHED
CABLE INSPECTION |
 |
|
|
|
|
|
| 1)
Conductor Resistance |
Double Kelvin
Bridge |
100% |
As per IS
& BS Standards. |
Review by
Client |
| |
Digital Ohm meter |
|
|
Review by Client |
| 2) High Voltage
Test |
High voltage
tester |
100% |
As per IS
& BS Standards. |
Review by
Client |
| 3) Volume resistivity |
Insulation resistance meter |
|
As per IS & BS Standards. |
Review by Client |
| 4) Dimensional
Check |
vernier calliper |
100% |
As per IS
& BS Standards. |
Review by
Client |
| 5) Thickness of insulation
& Jacket |
vernier calliper |
100% |
As per IS & BS Standards. |
Review by Client |
| 6) Insulation
Resistance constant |
Insulation
resistance meter |
100% |
As per IS
& BS Standards. |
Review by
Client |
| 7) Armour resistance test (For
Mining Cable) |
Micro Ohm Meter |
100% |
As per IS & BS Standards. |
Review by Client |
 |
|
|
|
|
|
| 1) Annealing
test on Copper. |
Tensile testing
m / c |
per core |
As per IS-8130 |
Witness by
Client |
| 2) Conductor diameter |
micrometer |
per core |
As per IS-8130 |
Witness by Client |
| 3) Conductor
resistance |
Electrical
Test / Digital micro ohm meter |
100% |
As per IS-8130 |
Witness by
Client |
| 4) Thickness of Insul. / sheath |
measurement |
per core |
As per IS & BS Standards. |
Witness by Client |
| 5) High Voltage
Test at room temp |
Water tank,
HV tester |
As per IS |
As per IS
& BS Standards. |
Witness by
Client |
| 6) Tensile strength of PVC
/ insulation / sheath |
Tensile testing m / c |
As per IS |
As per IS & BS Standards. |
Witness by Client |
| 7) Elongation
of PVC / insulation / sheath |
Tensile testing
m / c |
Do |
As per IS
& BS Standards. |
Witness by
Client |
| 8) Insul. resistance Test |
I.R. Tester |
Do |
As per IS & BS Standards. |
Witness by Client |
| 9) Flammability
Test |
Flammability
Chamber |
Do |
As per IS
& BS Standards. |
Witness by
Client |
 |
|
|
|
|
|
| 1) Annealing test on Copper. |
Tensile testing m / c |
per core |
As per IS-8130 |
Review by Client |
| 2) Conductor
diameter |
micrometer |
per core |
As per IS-8130 |
Review by
Client |
| 3) Conductor resistance |
Electrical Test / Digital micro
ohm meter |
100% |
As per IS-8130 |
Review by Client |
| 4) Thickness
of Insul. / sheath |
measurment |
per core |
As per IS
& BS Standards. |
Review by
Client |
| 5) High Voltage Test at room
temp |
Water tank, HV tester |
As per IS |
As per IS & BS Standards. |
Review by Client |
| 6) Tensile
strength of PVC / insulation / sheath |
Tensile testing
m / c |
As per IS |
As per IS
& BS Standards. |
Review by
Client |
| 7) Elongation of PVC / insulation
/ sheath |
Tensile testing m / c |
Do |
As per IS & BS Standards. |
Review by Client |
| 8) Shrinkage test on PVC /
insulation / sheath |
Oven Scales |
Do |
As per IS & BS Standards. |
Review by Client |
| 9) Hot deformation test for
insulation / sheath |
Hot deformation test |
Do |
As per IS & BS Standards. |
Review by Client |
| |
appartus,
test apparatus, oven |
|
|
Review by
Client |
| 10) Ageing test for insulation
/ sheath |
Oven tensile testing m / c |
Do |
As per IS & BS Standards. |
Review by Client |
| 11) Loss
of mass test for insulaion / sheath |
oven, weighing |
Do |
As per IS
& BS Standards. |
Review
by Client |
| 12)Thermal Stability Test for
insulation / sheath |
Stability oven |
Do |
As per IS & BS Standards. |
Review by Client |
| 13) Insul.resistance
Test |
I.R.Tester |
Do |
As per IS
& BS Standards. |
Review by
Client |
| 14) Test for armour |
|
|
|
Review by Client |
| - wire dia
/ strip size |
vernier /
micrometer |
Do |
IS : 3975 |
Review by
Client |
| - Tensile test |
tensile tester meter |
Do |
IS : 3975 |
Review by Client |
| - Elongation
test |
tensile tester
meter |
Do |
IS : 3975 |
Review by
Client |
| - Resistivity test of armour |
resistance meter |
Do |
IS : 3975 |
Review by Client |
| - Mass of
zinc coating |
Chemical |
Do |
IS : 3975 |
Review by
Client |
| 15) Flammability Test |
Flammability Chamber |
Do |
As per IS & BS Standards. |
Review by Client |